LS-4B Water Meter Test Bench

LS-4B water meter test bench is a traditional test bench for over twenty years which is ideally used to test water meter DN15-50. It is in accordance with latest international standard ISO4064-4.

Description

GENERAL

LS-4B water meter test bench is a traditional test bench for over twenty years. It is used to test water meter DN15-DN50. Now adopt advanced technology in welding and polish treatment, 304 stainless steel and controlled by two-position four- way valve, flow rate adjusted by stainless steel ball valve, it can ensure the high accuracy, durability and nice appearance. With new function to take out and install the water meter, it is convenient in operation and easy for maintenance. LS-4B water meter test bench an ideal test bench used in water meter factories, water companies as well as measuring dept. It is in accordance with latest international standard ISO4064-4.

STRUCTURE AND PRINCIPLE

The basic water meter test bench is composed of the bench , clamp fixture, back and front straight pipe, flow meter group, standard measuring instrument and the outlet valve.

When the inlet is connected with the stable water source, the water will enter into the standard measuring instrument through the straight pipe. Compare the value of the checked water meter with that of the standard measuring instrument to get the reading error of water meter under test.

MAIN TECHNICAL SPECIFICATION

  1.  Accuracy of test bench: ±0.2%;
  2.  Diameter of water meter to be tested : φ15, φ20, φ25, φ40, φ50;
  3.  Can do overall performance test ( for the production)
  4.  Instantaneous flow indication: glass flow meter 4pcs LZB-15:4-90L/h; LZB-25:70-800 L/h; LZB-50:450-8000 L/h; LZB-80:7-31.5m3/h,Accuracy≤2.5% of actual value
  5.  Measuring chamber volume:

10-20L, 50-100L, 300-500L;

  1. Working Pressure: 0.25-0.4MPa;
  2. Clamp fixture adjust distance: 60mm
  3. With pressure test function (option), pressure of natural gas should keep between 0.25MP~0.6MP.
  4. Can test DN15 meter 7pcs, DN20 meter 6pcs, DN25 meter 5pcs, DN40 meter 1pc and DN50 meter 1pc. (When flow rate under Q3, can test DN15 4pcs, DN20 4pcs, DN25 4pcs, when flow rate under Q4 can test only one meter)