Description
General
TX08 series Iron Core Induced electromotive force (EMF) Tester is used to measure iron core induced electromotive force of various kind of ring type iron core made of different soft magnet material like permalloy, ultracrystalline or silicon sheet.
Measurement Principle
The iron core tester uses specialized testing wire, connect test bench through ring type iron core under test, to form a measuring loop with which primary and secondary of single turn.
Basic Specification
- Measuring range and resolution
Model Measuring range Resolution Accuracy TX08/1 Current 0-1.999A 0.001A Reading +-0.5%+full scale+-0.5% 0-19.99A 0.01A Voltage 0-1.999V 0.001V 0-19.99V 0.01V TX08/2 Current 0-19.99mA 0.01mA Reading +-0.5%+full scale+-0.5% 0-199.9mA 0.1mA 0-1999mA 1mA Voltage 0-19.99mV 0.01mV 0-199.9mV 0.1mV 0-1999mV 1mV - Input power frequency 50Hz, AC220V±10%, wave distortion coefficient<5%, power consumption under maximum current output <20VA
- Dimension: 45x35x25cm; weight: no more than 10kg